Abstract

Optical coherence tomography (OCT) is a high-resolution intravascular imaging technique that has shown promise for the early detection of intimal thickening of coronary arteries in pediatric heart transplant recipients. The potential utility of OCT as a diagnostic and/or prognostic tool is currently unclear due to a lack of a standardized approach to analyse OCT images in this population. We established the OCT Core Imaging Laboratory at BC Children’s Hospital to develop a standardized protocol for the quantitative analysis of OCT images. Our study population included n=30 pediatric cardiac transplant recipients who had OCT imaging of the coronary arteries performed as part of standard of care at BC Children’s Hospital (St Jude Medical, now Abbott). We deemed a ‘pullback’ analyzable if ≥10mm of the segment was of good image quality (defined as ≥75% of cross-section visible without artifact). We evenly selected 10-20 cross-sectional frames ≥1 mm apart, avoiding bifurcations. Using the device-manufacturer’s software, we applied digital planimetry to trace the lumen-intima border, the internal elastic lamina, and the external elastic lamina for each cross-sectional frame. Cross-sectional areas (CSA, mm2) were derived for the lumen, the intima and the media; maximal intimal thickness (mm) was defined as the widest point between the circular markers for the intima and media. We calculated the intima/media (I/M) CSA ratio. For each pullback, we derived summary values from cross-sectional frames for relevant variables as means, medians, 95th percentile (p95) and maximal values. We performed inter-rater and intra-rater reliability analyses by intra-class correlation coefficients and Bland-Atman Analyses. Overall, 82% of analyzable pullbacks met inclusion criteria for our protocol (≥10-20 frames, ≥1 mm apart), resulting in 67 pullbacks from 28 patients analysed. The right coronary artery was most frequently imaged (58%), and more often met inclusion criteria for quantitative analyses (85% vs. 82% overall). Mean vs. median and max vs. p95 summary statistics yielded very similar values for I/M CSA and maximal intimal thickness (all ICC>0.98; difference < 3%), suggesting our protocol provides robust summary values. We registered excellent inter-rater and intra-rater reliability for I/M CSA and maximal intimal thickness (all ICC>0.95; difference < 5%). We provide a systematically developed and rigorously tested protocol for the quantitative analysis of OCT images in children. The novel application of OCT to a pediatric population requires expert image analysis and has the potential to improve the care of pediatric transplant patients who are at risk of structural coronary changes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call