Abstract

Accurate monitoring of exposure to organic vapors, such as acetone, is an important part of maintaining a safe working environment and adhering to long‐ and short‐term exposure limits. Here, a novel acetone vapor detection system is described based on the use of a reactive chiral dopant in a nematic liquid crystal thin film, which can accurately monitor the total exposure over a given time frame through changes in the reflection band of the film. It is found that films exposed to 1000 parts per million by volume (ppmv) of acetone vapor for 2 h exhibit a shift in reflection band of 12 nm, with smaller shifts observed at lower concentrations of acetone. Such sensors have potential applications in industrial hygiene.