Abstract

Early detection of raised intracranial pressure (ICP) improves outcome in acute liver failure (ALF). We evaluated the feasibility of bedside, ultrasound-guided measurement of optic nerve sheath diameter (ONSD) in normal and ALF children and correlation of ONSD with grade of hepatic encephalopathy (HE), international normalized ratio (INR) and blood ammonia (BA). Forty-one ALF and 47 healthy children (5-18years) were prospectively enrolled and 12 hourly clinical evaluation was done. Laboratory parameters including INR and BA were recorded. ONSD was measured at admission, change in HE grade and at recovery in ALF, and once in controls. One hundred and twenty-one ONSD measurements (ALF-74, controls-47) were taken without complications. ONSD was 4.2 (3.9-4.3), 4.4 (4.0-4.6), 5.2 (4.8-5.8) and 3.9 (3.3-4.1) mm in controls, ALF without HE, with HE and at recovery respectively. ONSD was significantly higher in ALF with HE than those without HE. ALF without HE and at recovery had ONSD similar to controls. ONSD was higher in ALF with the clinical signs of raised ICP than those without (5.4 [4.9-5.7] vs 4.6 [4.1-5.3] mm; P=.01). ONSD of 4.6mm differentiated ALF with HE vs without HE and 5.1mm between poor vs good non-transplant outcome with ≥80% sensitivity and specificity. ONSD positively correlated with INR (r=.53, P<.001) and BA (r=.42, P=.002). ONSD can be safely and easily measured in ALF children and correlates with HE grade, INR and BA. Normal ONSD in children (>4years) is <4.5mm and value of >5.1mm in ALF requires urgent attention.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call