Abstract

Abstract The front-end electronics system for the Belle II Time-Of-Propagation (TOP) counter was fully installed in May 2016. The detector is a novel particle identification device for the barrel region, where Cherenkov ring images are reconstructed with precise timing information of each photon. The readout electronics need to have excellent timing performance for single photon detection. To exploit the benefit of high luminosity, the electronics must also be able to cope with a high input trigger rate (30 kHz) and have buffer memory which is deep enough to wait for a trigger decision ( > 5 μ s ). The TOP electronics has switching capacitor arrays to sample waveforms with 2.7 GSample/s, which allows a timing resolution of 50 ps for a single photon signal. The programmable logic and the processing system are the effective implementation to meet these requirements, where flexible optimization and step-by-step development of readout logic are possible. The system has been successfully operated in the first accelerator commissioning runs with beam collisions in 2018, where the typical trigger rate was 500 Hz . Operation with a 20 kHz trigger rate was also tested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.