Abstract

This paper describes the performance analysis of steam generators. Various energy conservation measures such as operating excess air level control and insulation condition and its impact on overall heat rate of a thermal power station are discussed. Study results show that the change in operating oxygen level in fl ue gas can give benefi t in unit heat rate to the tune of 10–40 kcal/kWh in 210 MW units and 10–50 kcal/kWh in 500 MW units. Reduction in the boiler skin temperature from 30°C to 10°C above the ambient dry bulb temperature will result in improvement in unit heat rate by 60 kcal/ kWh in 210 MW units and 80 kcal/kWh in 500 MW units.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.