Abstract
The ultrahigh-vacuum (UHV) protection system at the 2.5 GeV synchrotron radiation source (positron storage ring) at the Photon Factory allows the intense-photon-flux wiggler beamlines to operate safely during synchrotron radiation experiments for a long time. There are six high-power wiggler/undulator beamlines that provide intense photon-flux beams to the experimental hall. In the case of a possible instantaneous vacuum failure at the experimental hall, the intense photon-flux radiation from the wiggler could cause a meltdown of the titanium-alloy fast-closing valve. The authors have developed a UHV protection system. Upon a vacuum failure, the protection system can dump the positron beam by turning off the RF power in the four RF klystrons (150 kW maximum), and then initiate a blade closure of the fast-closing valve. In this paper, the operational performance of the vacuum protection system for the intense-photon-flux wiggler beamlines is evaluated and discussed regarding the actual vacuum deterioration downstream of a beamline at the experimental hall.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.