Abstract

In this paper, models for NOx emission prediction and denitration costs are built with support vector machine. The effects of the factors such as SCR inlet NOx content, unit load, oxygen content of exhaust gas, ammonia injection rate, air distribution condition, and coal type on NOx reduction are discussed. The denitration costs under different working conditions are calculated. The ammonia injection rate is optimized with genetic algorithm. It can be shown that the actual ammonia injection rate is 1%-3.5% lower than the optimal value.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.