Abstract
Oxygen permeation through Ba 0.5Sr 0.5Co 0.8Fe 0.2O 3− δ (BSCFO) perovskite tubular membranes was investigated under vacuum and elevated pressures conditions. This paper is focused on dependence of oxygen permeation flux on oxygen recovery, temperature and feed pressure. Oxygen flux decreases with the raise of oxygen recovery, more quickly when the recovery is larger than about 60%. Elevating the feed pressure speeds up the decrease of oxygen fluxes against oxygen recovery. Oxygen permeation flux increases with the feed pressure of air, however, the increment decreases gradually. Oxygen permeation flux and recovery increase with temperature gradually at a constant airflow rate and pressure. The permeation flux reached 9.5 cm 3/cm 2 min at an oxygen recovery of 48% under the condition of 925 °C and vacuum pressure of ∼100 Pa for permeation side and 7 atm for feed side. Long-term operation under vacuum and elevated pressure shows that oxygen purity larger than 99.4% can be obtained when silver was used as sealant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.