Abstract
Results of the investigation of the operation of explosive-driven high-voltage shock wave ferromagnetic generators (FMGs) in the open circuit and charging modes are presented. FMGs are based on the transverse (when the shock wave propagates across the magnetization vector M) shock demagnetization of Nd2Fe14B hard ferromagnetic energy-carrying elements of diameter 2.22 cm and length 2.54 cm (volume 8.5 cm3). In the charging mode the capacitance of capacitor banks was varied from 18 to 36 nF. The energy transferred to the capacitor bank reached 0.38 J. FMGs provided pulsed powers of 35-45 kW in times ranging from 10 to 15 mus. Computer codes were developed to digitally simulate the operation of the transverse FMG in the charging mode. Experimental results that were obtained are in a good agreement with the results of digital simulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.