Abstract

Test diodes made of detector grade Si have been irradiated by fluences up to 2.8 × 10 14 1 MeV neutrons per cm 2. We observe that signals from minimum ionising particles are produced with high charge collection efficiency (CCE∼70%) at relatively low forward bias voltages. The more usual reverse bias requires ∼10 times larger voltage to produce similar CCE.

Highlights

Read more

Summary

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.