Abstract

All soft x-ray beamlines at the Swiss Light Source (SLS) are served with variable polarization from APPLE II [1] type and electromagnetic undulators. Three APPLE II type undulators are used: a twin and a single standard APPLE II (UE56 and UE54) and a fixed gap APPLE II (UE44) which follows the adjustable-phase undulator approach by R. Carr [2], [3]. The demand to rotate the linear polarization vector from 0 – 180° required all four magnet arrays to be shiftable. This opened the possibility to also vary the energy by a suitable shift of the magnet arrays with a simplified support structure lacking in any gap drive system [4], [5]. The current photon beam quality in linear and circular mode and the pros and cons of the operation of the UE44 will be discussed, namely the underestimated influence of gradients in the complex field distribution. As a consequence the spectra are degraded, but can be recovered by use of distributed coils or by a simple change in the operation mode.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.