Abstract

Each long SOLEIL beamline, ANATOMIX and Nanoscopium, takes a photon beam from an in-vacuum undulator with a minimum gap of 5.5 mm. The canted radiation sources are installed in a long straight section of the storage ring. The first closure of both undulators led to the severe damage of the downstream undulator in 2011. The reason for this incident has been investigated and clearly identified. A long-term project has enabled us to find a technical solution for a simultaneous operation of both undulators. A special angle fast interlock was designed and a dedicated photon absorber has been introduced at the entrance of the second undulator while keeping the impact on the beam performance as low as possible. The main technical steps will be reported with an interim solution put in place in spring 2015 and a final solution deployed and validated in May 2016.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.