Abstract

Lithium-ion batteries are at the core of the democratisation of electric transportation and portative electronic devices. However, fast and/or low temperature charge induce performance loss, mainly through lithium plating, a degrading mechanism. In this report, 7Li operando Nuclear Magnetic Resonance spectroscopy is used to detect the onset of metastable lithium deposits in an NMC622/graphite cell at 0 °C and fast charge. An operando setup, compatible with low temperatures, was developed with special attention to the pressure applied on the electrodes/separator stack and noise reduction to enable early detection and good time-resolution. Direct detection of metallic lithium enables drawing correlations between lithium plating and electrochemical data.

Full Text
Published version (Free)