Abstract

Accurate understanding of internal phenomena and their feedback is intrinsically important for improving the performance and durability of proton exchange membrane fuel cells. The oxygen partial pressure (p(O2)) at 10 μm from the cathode catalyst layer (CL) in the gas diffusion layer was measured by using an optical fiber with an oxygen-sensitive dye applied to the apex, when the current density was abruptly increased. p(O2) decreased with increasing current density at constant air utilization. This decrease in oxygen partial pressure is attributed to the increased amount of water at the CL at the cathode due to the oxygen reduction reaction and electro-osmotic drag, as previously proposed. A shortage of oxygen in the CL for 1 s was also detected by using this p(O2) monitoring. These results are consistent with the previous results obtained by operando time-resolved measurements of the water distribution in the electrolyte membranes of a running fuel cell.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.