Abstract

Monitoring the dynamic chemical and thermal state of a cell during operation is crucial to making meaningful advancements in battery technology as safety and reliability cannot be compromised. Here we demonstrate the feasibility of incorporating optical fibre Bragg grating sensors into commercial 18650 cells. By adjusting fibre morphologies, wavelength changes associated with both temperature and pressure are decoupled with high accuracy, which allows tracking of chemical events such as solid electrolyte interphase formation and structural evolution. We also demonstrate how multiple sensors are used to determine the heat generated by the cell without resorting to microcalorimetry. Unlike with conventional isothermal calorimetry, the cell’s heat capacity contribution is readily assessed, allowing for full parametrization of the thermal model. Collectively, these findings offer a scalable solution for screening electrolyte additives, rapidly identifying the best formation processes of commercial cells and designing battery thermal management systems with enhanced safety.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.