Abstract

This paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric drive system has particular operating characteristics either in healthy states or in the faulty ones. Two original contributions are considered in this paper. They consist in normalizing the input variables of the FDI process applied to multiphase system and compensating the noise (switching and sensors noises) and dc-component resulting from the fault occurrence. The proposed strategy uses multiple normalized criterias derived from the measured phase currents and the references currents obtained from the outputs of the speed controllers. The FDI shows independence with respect to transient states and to switching and measurement noises. Moreover, it can be easily included in an existing software without any additional sensors. The validity of the proposed method is verified by Matlab/Simulink simulation tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.