Abstract

This work proposes fault-tolerant schemes for open-transistor faults applied to three-phase dual active bridge converters (TPDABC), using different transformers: star-star, delta-delta, and delta-star. The proposal consists of operating the TPDABC as a single-phase dual active bridge converter, modifying the modulation strategy. This strategy avoids the need for additional components, which allows the converter to continue operating after an event of open transistor failure. The expressions of the average power when the converter operates in the fault-tolerant modes are determined. The analysis determines that the maximum power that can be transferred using the transformer delta-star is larger than the power obtained for star-star and delta-delta connections. Simulation results allow the proposed schemes to be validated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.