Abstract
BackgroundRecurrences have been a significant problem following hernia repair. Prosthetic materials have been increasingly used in hernia repair to prevent recurrences. Their use has been associated with several advantages, such as less postoperative pain, rapid recovery, low recurrence rates.MethodsIn this retrospective study, 540 tension-free inguinal hernia repairs were performed between August 1994 and December 1999 in 510 patients, using a polypropylene mesh (Lichtenstein technique). The main outcome measure was early and late morbidity and especially recurrence.ResultsInguinal hernia was indirect in 55 % of cases (297 patients), direct in 30 % (162 patients) and of the pantaloon (mixed) type in 15 % (81 patients). Mean patient age was 53.7 years (range, 18 – 85). Follow-up was completed in 407 patients (80 %) by clinical examination or phone call. The median follow-up period was 3.8 years (range, 1 – 6 years). Seroma and hematoma formation requiring drainage was observed in 6 and 2 patients, respectively, while transient testicular swelling occurred in 5 patients. We have not observed acute infection or abscess formation related to the presence of the foreign body (mesh). In two patients, however, a delayed rejection of the mesh occurred 10 months and 4 years following surgery. There was one recurrence of the hernia (in one of these patients with late mesh rejection) (recurrence rate = 0.2 %). Postoperative neuralgia was observed in 5 patients (1 %).ConclusionLichtenstein tension-free mesh inguinal hernia repair is a simple, safe, comfortable, effective method, with extremely low early and late morbidity and remarkably low recurrence rate and therefore it is our preferred method for hernia repair since 1994.
Highlights
Recurrences have been a significant problem following hernia repair
We review our experience on tension – free surgical repair of a consecutive series of inguinal hernias using a polypropylene mesh (Lichtenstein technique)
From August 1994 through December 1999, 540 tension – free repairs of inguinal hernia were performed in 510 patients, by using a polypropylene mesh (Surgi-Pro in 95 % and Prolene in 5 %)
Summary
Recurrences have been a significant problem following hernia repair. Prosthetic materials have been increasingly used in hernia repair to prevent recurrences. Their use has been associated with several advantages, such as less postoperative pain, rapid recovery, low recurrence rates. Recurrence following repair of inguinal hernias is a significant problem for both the surgeon and the patient. The use of such a weakened tissue is problematic for hernia repair. The reports by Stoppa et al [5] and by Lichtenstein [6], as well as the innovation of laparoscopic hernia repair [7,8], where the use of prostheses was associated with many advantages, greatly contributed to this change in our surgical philosophy. We review our experience on tension – free surgical repair of a consecutive series of inguinal hernias using a polypropylene mesh (Lichtenstein technique)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.