Abstract
This paper presents a novel method to control sinusoidal distributed winding or sinusoidal back electromotive force (back-EMF) multi-phase permanent magnet (PM) machines under open-circuit fault conditions. In this study, five different fault conditions are considered: single-phase, adjacent double-phase, non-adjacent double-phase, adjacent three-phase, and non-adjacent three-phase open circuit conditions. New current sets for the remaining healthy phase under open-circuit fault conditions are obtained by compensating the direct-quadrature (d-q) axes currents. For this purpose, an iterative method has been used to get the new set of currents. D-q axes currents, due to faulty phase/phases, are shared to the healthy phases to obtain the same d-q axes currents as in the healthy condition. Therefore, the same torque is produced as in the healthy condition. The developed method is simulated in MATLAB/Simulink by using a d-q modelled sinusoidal back-EMF five-phase machine. A vector control block diagram has been designed to run the machine under healthy and faulty conditions. The machine model has been run successfully under fault tolerant conditions. Additionally, a finite element analysis (FEA) has been undertaken to simulate the five-phase PM model machine by using MagNet software. Open-circuit fault-tolerant control currents are fed into the coils of the machine model. Satisfactory torque results have been obtained. Because the model five-phase PM machine includes higher order back-EMF harmonics, especially the third harmonic, torque has ripple due to interaction between the fault-tolerant control currents and the higher order back-EMF harmonics.
Highlights
In recent years, multi-phase machines have garnered interest from researchers due to their various beneficial features [1]
Applying the proposed method to obtain the remaining healthy phase currents, resultant magnetomotive force (MMF) are shown in Figure 3b–d after the 1st, 2nd, and 8th iteration, respectively
The d-q axis currents that are in the healthy condition have been used as reference currents by assuming these currents are positioned for the maximum torque
Summary
Multi-phase machines have garnered interest from researchers due to their various beneficial features [1]. Sui et al [12] developed a fault-tolerant control strategy by keeping the current amplitude constant for five different open-circuit conditions in a five-phase machine. An open-circuit fault-tolerant control method has been presented for a five-phase machine by compensating the d-q axis currents. Amplitude of the currents can be set in the control block of the open-circuit fault-tolerant system according to the d and q axes voltages by using the vector control method
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.