Abstract

This paper demonstrates a fault detection and location for the open circuit (O.C) faults in the all power electronic converter stages including; the three-phase rectifier, the dc-dc converter, and finally the single-phase inverter. The proposed fault diagnosis is based on the adaptive neuro-fuzzy inference system (ANFIS) algorithm. The inputs to the ANFIS unit are the voltage and the current measurements of the power converter stages after they undergo several signal processing operations so that they could efficiently reflect the fault occurrence and behavior. The output of the ANFIS unit is utilized as an index in order to identify the O.C fault in the power converter. Then, it locates the fault within the three different stages of the converter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.