Abstract
There has been a proliferation of new sensors to measure on-machine dirt specks that employ different technologies and methodologies to perform measurements. The differences in the on-machine technologies are discussed in terms of the TAPPI and ISO standard laboratory test methods with respect to dirt detection using light reflected from, or light transmitted through, the sheet. Also discussed are the requirements for measuring statistically representative areas of the sheet; the difference between the dirt physical size and Equivalent Black Area (EBA) size; and the implication of these issues when specifying cleanliness acceptance criteria. This technical brief describes on-machine visible dirt measurement’s relationship to standard laboratory testing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.