Abstract

The potential of online trace enrichment on a highly apolar short column in LC was evaluated for the determination of pyrethroids in river water. Twelve millilitres of water samples, modified with 8 mL ACN (ACN/water 40:60, v/v), were passed through 50 x 4.6 mm ID first separation column packed with 5 microm Hypersil Elite C18. Pesticides were preconcentrated in this column while the matrix background was eluted to waste. Separation of pesticides was performed on a 3.5 microm symmetric C18 column (250 x 4.6 mm ID) with an ACN step gradient as mobile phase and fluorescence detection was used after postcolumn derivatization by using UV light. The use of photochemically induced fluorescence for detection improved sensitivity and selectivity. Quantification limits ranged from 0.05 to 0.1 microg/L and pesticide recoveries at two concentration levels (0.1 and 0.5 microg/L) were between 93.1 and 118.6%, with RSD between 2.5 and 7.5% (n = 3) in river water samples. No matrix effect was detected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.