Abstract

AbstractThe applicability of online total harmonic distortion analysis (THDA) for the operation and monitoring of solid oxide fuel cell (SOFC) power systems is investigated by experiments as well as analysis of the algorithm, with a focus on the relationship between stack fuel utilization rate and the corresponding THD index. An online THDA algorithm is implemented in a programmable logic controller (PLC) and operated with a 6 kW SOFC power system demonstration unit. Laboratory experiments on the solid oxide fuel cell technology are carried out to determine key parameters for the algorithm. The embedded implementation of the THDA algorithm, including several modifications to reduce its computational load, and its parameterization is analyzed and the program code is given in the Appendix. The experimental results verify that THDA can be a reliable means for quantitatively monitoring the fuel utilization rate experienced by the stack and that the algorithm is simple to implement on an embedded controller.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.