Abstract

In this paper an on-line radioiodine monitoring system designed to operate under nuclear accident conditions is tested at the hot cell laboratory of a radiopharmaceutical production facility. The purpose of the work is to demonstrate that the patented Pennsylvania State University radioiodine monitor, using stabilized NaI(Tl + {sup 241}Am) detectors, can generate information about concentration of airborne radioiodine in real time. In the test of continuous iodine monitoring, the real-time {sub 132}I activities agree with those obtained by a high-purity germanium detector within a factor of {approximately}4. From the simultaneous operation of two monitors, one at the inlet and one at the outlet of the hot cell filter band, the hot cell filter bank efficiency for the removal of airborne radioiodine is estimated to be at least 99.88%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.