The ANURIB facility being planned at VECC will use a super-conducting electron linac (e-Linac) as photo-fission driver. The e-Linac will initially be of 30 MeV, 2 mA with an optional upgrade to 50 MeV planned in the future. An identical e-Linac is being built for the ARIEL project at TRIUMF, Canada. The 30 MeV e-linac is made using three 1.3GHz nine cell niobium cavities of Cornell-type, each cavity supplying 10 MV acceleration. The first 9-cell cavity is housed in a cryomodule called Injector Cryomodule (ICM) followed by an Accelerator Cryo-Module (ACM) comprising two 9-cell cavities. In the first phase, the ICM has been developed in collaboration with TRIUMF. The cavity operates at 1.3 GHz and 2 K. The paper highlights the online quality factor measurement of the ICM using calorimetric method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.