Abstract

In this study, an automatic sampling device and an analysis device have been developed for the measurement of low-volatile organic chlorine (LVOCl) in flue gas. The concentrations of dioxins (polychlorinated dibenzo- p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls) have been estimated by online measurements of LVOCl at a municipal solid waste incinerator (MSWI) using these devices. The LVOCl concentration at the outlet of the selective catalyst reactor (SCR) of the MSWI increased momentarily up to 95 μg Cl m −3 during the startup period of the MSWI; subsequently, it gradually decreased to less than 1.0 μg Cl m −3 after 50 h from the start of waste feeding. The concentration of toxic equivalent quantity (TEQ)-Dioxins at the SCR outlet had a linear positive relationship with the LVOCl concentrations. Moreover, the level of TEQ-Dioxins concentration can be estimated by using this relationship with LVOCl. From our results, since the LVOCl concentrations in a flue gas can thus be automatically analyzed every hour by online measurements, the operators of an MSWI would be able to monitor approximate TEQ-Dioxin emissions on a daily basis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.