Abstract

The key quality factor for reliable deep penetration laser welding processes is a correct penetration depth. Today, this parameter is only accessible by offline quality control methods. Since the reliability of a butt-joint strongly depends on the penetration depth, it is desirable to have a possibility to measure and control the penetration depth online during the welding process.A sensor for measuring the penetration depth has to fulfill several requirements: Illumination and detection has to be coaxially to the high power laser, since the capillary can be very deep and slender. The measurement has to work despite of a very high dynamic range of the detected light and despite of strong background radiation from the welding process. The sensor should realize scan rates in the kilohertz range to enable real time closed loop control of the welding process with high control frequency. The penetration depth should be measured with a resolution in the range of 100 µm.Today no sensor exists that fulfills these requirements. Different approaches, like in [1] and [2], were discussed in the past, but none of them has emerged to a fast and reliable measuring product.The key quality factor for reliable deep penetration laser welding processes is a correct penetration depth. Today, this parameter is only accessible by offline quality control methods. Since the reliability of a butt-joint strongly depends on the penetration depth, it is desirable to have a possibility to measure and control the penetration depth online during the welding process.A sensor for measuring the penetration depth has to fulfill several requirements: Illumination and detection has to be coaxially to the high power laser, since the capillary can be very deep and slender. The measurement has to work despite of a very high dynamic range of the detected light and despite of strong background radiation from the welding process. The sensor should realize scan rates in the kilohertz range to enable real time closed loop control of the welding process with high control frequency. The penetration depth should be measured with a resolution in the range of 100 µm.Today no sensor exists that fulfills thes...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.