Abstract

Gamma dose-rate profiles have been measured by means of a self-powered gamma detector (SPGD) in a gamma irradiation facility using /sup 60/Co sources, situated in the side pool of the BR2 materials testing reactor. Because of its small size (diameter of only 4 mm), the SPGD is ideally suited to perform very localized gamma dose-rate measurements. It has been shown that the SPGD can provide precise relative measurements of the local gamma dose rate in the range 0.5-20 kGy/h. A very detailed Monte Carlo code has been developed to relate the gamma dose rate (for a given gamma spectrum) to the current induced by the SPGD. The obtained conversion factor could thus be used to determine the absolute gamma dose rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.