Abstract
The main objective of this paper is to develop a new technique for detecting turn-to-turn short-circuit faults in one or two stator phases of an induction motor. Hence, modeling a turn-to-turn short-circuit fault in more than one phase and a phase-to-ground fault is the first novelty of this paper for calculating phase currents under faulty conditions. This strategy uses the extracted features from the corresponding three-phase current pattern in 3-D space. Identification of faulty phases and of the severity of the fault is the outcome of this technique. This technique is also capable of detecting a phase-to-ground fault. This method just requires current sensors that are available in most drive systems to provide good controllability, and details of the machine design are not necessary. Experimental results are included to show the ability of the proposed strategy for detecting and locating phase/phases under different faults and load conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.