Abstract

In this paper, we examine the problem of extrinsic calibration of multiple LIDARs on a mobile vehicle platform. To achieve fully automated and on-line calibration, the original non-linear calibration model is reformulated as a second-order cone program (SOCP). This provides an advantage over more standard linearized approaches in that a priori information such as a default LIDAR calibration, calibration tolerances, etc., can be readily modeled. Furthermore, in contrast to general non-linear methods, the SOCP relaxation is convex, returns a global minimum, and can be solved very quickly using modern interior point methods (IPM). This enables the calibration to be estimated on-line for multiple LIDARs simultaneously. Experimental results are provided where the approach is used to successfully calibrate a pair of Sick LMS291-S14 LIDARs mounted on a mobile vehicle platform. These showed the SOCP formulation yielded a more accurate reconstruction and was 1–2 orders of magnitude faster than the traditional non-linear least-squares approach.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.