A simple online autotuning technique for a resonant converter to achieve output voltage regulation while tuning the switching frequency to the resonant frequency is proposed in this paper. The proposed method can deal with resonant frequency variation caused by the resonant components: tolerance and variation. The proposed technique is developed by detecting the zero-crossing point and peak point of resonant current. Moreover, the correction term of dc bus voltage reference is generated based upon the error between switching period (frequency) and resonant period (frequency). The voltage reference of power factor corrector output voltage is, thus, tuned to achieve both switching frequency tracking and output voltage regulation of resonant converter. The proposed method is simple and no knowledge of resonant frequency is required in prior. The proposed method is realized in software using DSP. Test results derived from a digital-controlled server power show that switching frequency can track the resonant frequency well even with large variation of resonant components. These measured results fully support the effectiveness of the proposed technique.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.