Abstract
A novel one-step separation strategy-tandem high-speed counter-current chromatography (HSCCC) was developed with a six-port valve serving as the switch interface. Nine structural analogues including three isomers were successfully isolated from Poria cocos (Schw.) Wolf. by one step. Compared with conventional HSCCC, peak resolution of target compounds was effectively improved in tandem one. Purities of isolated compounds were all over 90% as determined by HPLC. Their structures were then identified via UV, MS and (1)H NMR, and eventually assigned as poricoic acid B (1), poricoic acid A (2), 3β,16α-dihydroxylanosta-7, 9(11), 24-trien-21-oic acid (3), dehydrotumulosic acid (4), polyporenic acid C (5), 3-epi-dehydrotumulosic acid (6), 3-o-acetyl-16α-hydroxydehydrotrametenolic acid (7), dehydropachymic acid (8) and dehydrotrametenolic acid (9) respectively. The results indicated that tandem HSCCC can effectively improve peak resolution of target compounds, and can be a good candidate for HSCCC separation of structural analogues.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.