Abstract

Work domain analyses can be time consuming, requiring extensive interviews, documentation review, and observations, among other techniques. Given the time and resources required, we examine how to generalize a work domain analysis technique, namely the hybrid Cognitive Task Analysis (hCTA) method across two domains in order to generate a common set of display information requirements. The two domains of interest are field workers troubleshooting low voltage distribution networks and telecommunication problems. Results show that there is a high degree of similarity between the two domains due to their service call nature, particularly in tasking and decision-making. While the primary differences were due to communication protocols and equipment requirements, the basic overall mission goals, functions, phases of operation, decision processes, and situation requirements were very similar. A final design for both domains is proposed based on the joint requirements.