Abstract

Corrosion of steel bars used in reinforced concrete bridge decks exposed to moisture and deicing salts is of concern. The chloride-induced corrosion of steel reinforcement increases the maintenance cost of the structure. The resistance of glass fiber reinforced polymer (GFRP) reinforcing bars to corrosion provides a viable alternative to steel reinforcement. Lightweight concrete allows structural members to have a reduced weight, which is advantageous for lifting and moving operations when precast concrete elements are used. This paper evaluates the one-way shear capacity of lightweight concrete panels reinforced with GFRP reinforcement. Three normal weight concrete and three lightweight concrete specimens reinforced with identical GFRP reinforcement details were tested to failure. The results of the tests are compared with the shear strength predictions of the American Concrete Institute (ACI) 440.1R-06 recommendations and a theoretical model based on the modified compression field theory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.