Abstract
Referral for abnormal liver chemistry is one of the most frequently encountered reasons for visits to gastroenterologists and hepatologists, particularly given the versatility and vulnerability of the liver.1Kwo P.Y. Cohen S.M. Lim J.K. ACG clinical guideline: evaluation of abnormal liver chemistries.Am J Gastroenterol. 2017; 112: 18-35Crossref PubMed Scopus (395) Google Scholar Here, we present a 40-year-old man with class III obesity, essential hypertension, and hyperlipidemia who was referred for further diagnostic workup of his abnormal liver chemistry. Despite periods of significant weight loss, his liver transaminases had remained elevated over the prior 10 years (alanine aminotransferase 20-93 U/L, aspartate aminotransferase 20-71 U/L). Diagnostic workup included an abdominal ultrasound with evidence of hepatic steatosis and transient elastography (Fibroscan) that demonstrated a liver stiffness of 12.8 kPa, S3 (marked steatosis), and F3 (severe fibrosis). After reviewing the risks, benefits, and alternatives, the decision was made to perform an EGD to evaluate for stigmata of portal hypertension and an EUS to obtain a liver biopsy specimen and portal pressure gradient (PPG) measurements. The patient was intubated and remained in the supine position for the entirety of the procedure (Video 1, available online at www.VideoGIE.org). Initially, an EGD was performed, with no endoscopic evidence of varices or stigmata of portal hypertension. Next, the EUS examination was performed. The left lobe of the liver appeared diffusely hyperechoic, suggestive of steatosis. Real-time elastography was then performed on the left and right lobes of the liver to assess liver stiffness. The region of interest was positioned over the hepatic parenchyma, and an average of 10 measurements was obtained from each lobe of the liver. Mean liver stiffness was 11.5 kPa. The EchoTip Insight Portosystemic Pressure Gradient Measurement System (Cook Medical, Bloomington, Ind, USA) then was set up, involving a 25-gauge FNA needle, noncompressible tubing, a compact digital manometer, and heparinized saline solution. The middle hepatic vein was first identified and punctured using a transgastric approach. Once the needle tip was seen within the vessel, approximately 1 to 2 mL of heparinized saline solution was used to flush the needle. The pressure reading on the manometer was obtained and recorded once stable. This process was repeated a total of 3 times, including repeat flushes of heparinized saline solution to obtain the mean hepatic vein pressure measurement. Next, the umbilical portion of the left portal vein was identified, and using the aforementioned approach, the process was repeated 3 times to obtain the mean portal vein pressure measurement. The PPG was calculated by subtracting the mean hepatic vein pressure (16.4 mm Hg) from the mean portal vein pressure (23.4), which measured 7 mm Hg (consistent with preclinical portal hypertension). Last, EUS-guided liver biopsy was performed. Using a 19-gauge EUS–fine needle biopsy needle primed with heparin, we performed a transgastric puncture to obtain a sample from the left lobe of the liver. This process was then repeated using a transduodenal approach to obtain tissue from the right lobe of the liver. Liver core was then expressed onto a slide and sent to surgical pathology. The patient was discharged home after endoscopy without any adverse events. Surgical pathology from the liver biopsy revealed mild steatohepatitis with stage 0-1/4 fibrosis (Fig. 1). On outpatient follow-up, the patient was started on a stricter diet and exercise regimen for weight loss. EUS-guided applications have been increasing over the past decade; today, both endoscopy and echoendoscopy offer tremendous diagnostic information to help guide management in the workup of liver disease.2Samarasena J. Chang K.J. Endo-hepatology: a new paradigm.Endosc Ultrasound. 2018; 7: 219-222Crossref PubMed Scopus (6) Google Scholar In particular, EUS-guided liver biopsy has emerged as a safe and minimally invasive approach and an alternative to a percutaneous technique and now can be paired with EUS-guided real-time elastography and PPG measurement.3Huang J.Y. Samarasena J.B. Tsujino T. et al.EUS-guided portal pressure gradient measurement with a simple novel device: a human pilot study.Gastrointest Endosc. 2017; 85: 996-1001Abstract Full Text Full Text PDF PubMed Scopus (61) Google Scholar,4Shah A. Martinez I.C. Valentin N. et al.Efficacy and safety of endoscopic ultrasound-guided liver biopsies in parenchymal liver diseases: a systematic review and meta-analysis.Am J Gastroenterol. 2018; 113: S565-S566Crossref Google Scholar Here, we demonstrate the safety and technique of EUS-guided PPG measurement in the diagnostic workup of abnormal liver tests. Dr Sharaiha is a consultant for Boston Scientific and Apollo Endosurgery (terminated). All other authors disclosed no financial relationships. https://www.videogie.org/cms/asset/91a9cbf3-9569-4652-812c-a82edde33120/mmc1.mp4Loading ... Download .mp4 (65.17 MB) Help with .mp4 files Video 1“One stop” liver-focused endoscopy: EUS-guided portal pressure gradient measurement technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.