Abstract

Accurate predictions of two-phase pressure drop in small to micro-diameter passages are necessary for the design of compact and ultra-compact heat exchangers, which find wide application in process and refrigeration industries and in the cooling of electronics. A semimechanistic model of boiling two-phase pressure drop in the confined bubble regime is formulated, following the three-zone approach for heat transfer. The total pressure drop is calculated by time-averaging the pressure drops for single-phase liquid, elongated bubble with a thin liquid film, and single-phase vapor. The model results were compared with experimental data collected for a wide range of tube diameters (4.26, 2.88, 2.02, 1.1, and 0.52 mm) for R134a at pressures of 6–12 bar. In this model's present form, its predictions are close to those of the homogeneous flow model but it provides a platform for further development.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.