Abstract

The National Institute of Standards and Technology has developed the capability to measure noise parameters on a wafer in the 1-12.4-GHz range. The authors describe the measurement method and the uncertainty analysis and present results of measurements on a highly reflective transistor. Typical standard uncertainties are within the range of 20-25 K in T <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">min</sub> , which is the minimum transistor noise temperature, and about 0.03 in the magnitude of Gamma <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">opt</sub> , which is the reflection coefficient for which T <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">min</sub> occurs

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.