Abstract

Besides the imbalance between the voltages of internal and external power device, the NPC three-level inverter with the 3RCD snubber circuit has a large short-circuit current in the commutation path, which increases the current stress of the power devices, and even endangers the regular operation of the power devices. In this paper, the four kinds of short-circuits generated by 3RCD in a three-level NPC inverter are presented, and their reasons are also analyzed. Theoretical analysis is verified by the simulation and experiments. The result shows that the 3RCD snubber circuit with the above shortcomings is not enough excellent to be used in high-power NPC three-level IGBT inverters. More effective methods should be proposed to suppress the transient over-voltage of IGBT.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.