Abstract

Gas flow in long, narrow, very shallow, micromachined silicon dioxide–quartz glass channels was studied with the use of a mass spectrometric system. The channel bottom was partly covered with an evaporated, 10-Å-thick platinum film along its whole length, and the channel was inserted as the only leak between a gas mixing chamber and an ultrahigh vacuum mass spectrometer chamber. At a wide pressure range upstream of the channel (10–1000 Torr), the steady state flow through the channel was characterized as being close to molecular. At a pressure buildup of either H2 or O2 in the gas mixing chamber, the mass spectrometer response was delayed more than what can be explained by molecular diffusion. A total restriction of the diffusion due to adsorption on platinum is suggested. The assumption is in accord with different validation experiments. A model for the adsorption delay time is presented and discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.