Abstract

With 25 organic molecules that represent popular functional groups, we tested the transferability of force field parameters using both parametrized force fields CHARMM, CFF, and MMFF and generic force fields DREIDING and UNIVERSAL. We found that, if transferred parameters are used in a parametrized force field, the calculation quality is no longer superior to that of a generic force field. To achieve high quality in predictions, new parameters should be created from ab initio data whenever necessary. We investigated this approach and found that a custom-built force field can be made to reproduce ab initio results if parameters are derived specifically for the molecules of interest. The parametrization procedure was applied to a group of classic antibacterial drug molecules, the sulfonamides.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.