Abstract
Abstract The paper discusses the theoretical background in terms of the use of in-phantom recombination chambers in mixed radiation fields, with special attention paid to the question of how the experimentally determined, linear-energy-transfer-dependent (LET) parameters can be applied with regard to the more accurate determination of the chamber response and absorbed dose in mixed radiation fields. Methods of taking the recombination index of radiation quality (RIQ) measurements and theoretical consideration concerning the determination of the absorbed dose are described. Classical Bragg-Gray and Spencer-Attix cavity theories were analysed and their relationship to in-phantom recombination chambers was specifi ed. Methods concerning the estimation of correction factors with regard to RIQ measurements and their importance are highlighted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.