Abstract

The retarding field analyzer (RFA) is one of the only widely accepted diagnostics for measurements of ion temperature Ti in the tokamak scrape-off layer. In this paper we analyze some instrumental effects of the RFA and their influence on Ti measurements. It is shown that selective ion transmission through the RFA slit is responsible for an overestimation of Ti by less than 14%, even for a relatively thick slit plate. Therefore, thicker slit plates are preferable, since they reduce, e.g., the risk of melting during off-normal events, and the effect of positive space charge inside the cavity. The influence of the electron repelling grid, as well as misalignment of the slit with respect to the magnetic field on Ti measurements are negligible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.