Abstract

In this work, we attempt to overcome the problem of non-uniformity of large-area capacitively coupled plasmas. We select a multi-electrode concept and construct a system with two concentric electrodes. In the two-circuit model, both electrodes have the same area. The plasma of this system is measured by a two-dimensional probe array. We measure the plasma in the large-area chamber that has the multi-electrode. We reduce the non-uniformity to almost 3% and investigate the conditions of a uniform plasma.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.