Abstract

High performance absorption heat transformers based on improved configurations can be proposed with the aim of widening the range of operation of the single stage heat transformer (SSHT). In this paper a two stage heat transformer arranged by coupling the absorber of the first stage to the evaporator of the second stage (TSHT) is analyzed by means of a lumped-parameter mathematical model, written with reference to the water-sulphuric acid system. The computed values of four different indexes of performance show that the proposed TSHT allows one to noticeably increase the gross temperature lift obtainable with a SSHT, while saving a large fraction of the input energy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.