Abstract
This paper is devoted to elucidation of the question: Which external pressure is required to stop skin blood flow at the skin - support interface in humans lying on the back in the supine position? Cessation of blood flow was recorded as cessation of washout of an intracutaneous depot of 131I-antipyrine mixed with histamine. The external pressure was measured by a small airfilled plastic cushion connected to a mercury manometer. In 11 normal subjects, eight patients with hypertension and seven patients with tetra- or paraplegia the "flow cessation external pressure" (FCEP) was strongly correlated to the auscultatory brachial mean blood pressure (p less than or equal to 0.001). The difference mean blood pressure - FCEP was on average 4 mmHg (range (-11) - (+20) mmHg) and there was no significant difference between the three groups studied. Thus external pressure exceeding the actual mean blood pressure will stop skin circulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Scandinavian journal of plastic and reconstructive surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.