Abstract
Frictional pressure drop (also called wall drag) for a two-phase flow has been investigated for several decades. However, the two-phase frictional pressure drop models in the state-of-the-art thermal-hydraulic system codes are significantly different from each other, especially in the way to partition the wall friction force of liquid and vapor phases in the two-fluid momentum equations. This may lead to unphysical results in some flow conditions.In this technical note, the two-phase wall frictional pressure drop models in the RELAP5/MOD3, TRACE V5, and SPACE codes are discussed in terms of the wall friction partition into the liquid and vapor momentum equations. To show the effect of different partition methods in the three codes, we simulated air-water bubbly flows in a horizontal pipe. The results of the calculations show that the partition method has a direct effect on the relative velocity of the two phases, and it may lead to unphysical behaviors of dispersed bubbles and droplets. It is strongly recommended to revisit the two-fluid formulation and the partition method of two-phase wall drag in the state-of-the-art system codes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.