Abstract

Chromium is a good candidate for obtaining conductive ultra-thin layers on insulator substrates such as quartz. The resistivity of such layers is highly related to the quality of the deposited chromium film. In order to optimize the deposition process, there is a need for rapid and accurate monitoring of such films (film thickness, thickness uniformity over a big surface, etc.). In this paper, we demonstrate the ability of the LE-PIXE technique, using proton energies <1MeV, for the monitoring of the thickness and the thickness uniformity of ultra-thin (0.5nm<t<20nm) chromium layers deposited onto quartz substrates. The acquisition time needed to obtain results with less than 3–4% precision was ∼5min for the thinnest layers. The validation for the use of the LE-PIXE technique was checked by means of conventional RBS technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.