Abstract
Using synchronized rapid video imaging and calibrated acoustic emission (AE) measurements, a direct correspondence is found between the length of emerging twin and its AE transient response during in-situ testing of Mg polycrystals. The detectability limit for twin nucleation in Mg and its alloys is evaluated to be as small as 0.3µm or even less. It is shown that the use of appropriate calibration procedures enables quantitative evaluation of the kinetics of twinning by means of an advanced AE technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.