Abstract

The thermal degradation of PVC was studied at 190°C in pure nitrogen and nitrogen containing 10, 20, and 40% HCl (by volume). The rate of dehydrochlorination was determined by gravimetry. Degradations in nitrogen were followed with conductometry in addition. Changes in molecular weight distribution and degree of long-chain branching (LCB) were determined by gel permeation chromatography–viscometry and polyene sequence distribution by UV spectroscopy. The rate of dehydrochlorination increases with the HCI content of the atmosphere. The rate of molecular enlargement also increases but only as a result of the increased dehydrochlorination rate. The increase in Mw and LCB are thus related to the extent of conversion only. Changes in the UV spectra indicate that the increase in rate of dehydrochlorination is mainly due to increased propagation rate in atmospheres containing less than 10% HCI. At higher HCI contents an increase in initiation rate is noted. It is suggested that this, at least in part, is due to the fact that HCI, by forming a cyclic transition state, catalyzes the random elimination of HCI. This process, in turn, is promoted by the presence of polyene sequences.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.