Abstract

This paper treats analytically the vibration prevention effect of the Houde damper which is attached to a main vibration system with positive or negative damping. Analyses about the damper of this type been done in the past only in the cases of a main system without damping. In this paper, the analyses are done both in the case of the main system with negative damping, that is a self-excited vibration system, and in the case of the main system with positive damping which is subjected to various alternate disturbing external forces. It is shown that better effect can be obtained in each case, if the optimum value of damping is given to the Houde damper with consideration of the damping of the main system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.